Charging Instructions for Pulsation Dampeners

SFU Series

SFU Series

Union Top Models - 100 cubic in.
  1. SFU o-ring
  2. SFU wing nut
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case
SFV-SFVM Series

SFV & SFVM Series

Magnum Grooved 8 in. Top Models - 600, 900 & 1200 cubic in
  1. 6″ or 8″ suction gasket
  2. 6″ or 8″ grooved coupling
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case
  8.  
SFU Series

SFT Series

Threaded Top Models - 300 & 600 cubic in
  1. HPG-1 gasket (Nitrile or EPDM)
  2. Dust cap
  3. Loading valve
  4. Bleeder valve
  5. Cartridge
  6. Case
SFV-SFVM Series

SFM Series

  1. SFM o-rings (2 required)
  2. SFM wingnut
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case
  8. SFM wingnut screw

Suction Charging Instructions

CHARGE TO 80%- 90% OF SUCTION PRESSURE OR THE MAXIMUM CHARGE PRESSURE OF THE CARTRIDGE, WHICHEVER IS LESS. THIS IS ONLY AN APPROXIMATION.

(YOU MAY FIND IT NECESSARY TO DECREASE THE PRESSURE IN THE SUCTION CARTRIDGE TO ACHIEVE OPTIMUM PUMP PERFORMANCE.)

Suction Charging Instructions
  • Shut down pump and relieve line pressure from discharge side before closing suction valve. After discharge line is relieved of pressure, close suction line valve and drain suction line.
  • Open bleeder valve ’A’.
  • Remove loading valve protector cap ’B’.
  • Remove cap from loading valve ’C’.
  • Loosen safety nut ’D’ three full turns.
  • Using NITROGEN ONLY, charge the cartridge through loading valve ’C’ to the recommended operating pressure (90% of suction pressure). (DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE).
  • Tighten safety nut ’D’ on loading valve ’C’.
  • Replace loading valve protector cap ’B’
  • Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.

Discharge Charging Instructions

  1. Shut down pump and relieve line pressure.
  2. Open bleeder valve ’A’.
  3. Remove loading valve protector cap ’B’.
  4. Remove cap from loading valve ’C’.
  5. Loosen safety nut ’D’ three full turns.
  6. Using NITROGEN ONLY charge the cartridge through loading valve ’C’ to correct charge pressure (Click here for chart).
    NOTE: DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE (ON CASE LABEL).
  7. Tighten safety nut ’D’ on loading valve ’C’ and replace cap.
  8. Replace loading valve protector cap ’B’.
  9. Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.
Discharge Charging Instructions

Nitrogen Charging Instructions

WARNING

THE USE OF ANY GAS OTHER THAN NITROGEN IS EXTREMELY DANGEROUS.

NEVER ATTEMPT TO CHARGE OR PRE-CHARGE A CARTRIDGE OUTSIDE OF THE PULSATION STABILIZER CASE.

FOR PROPER CHARGING PROCEDURES REFER TO THE SUCTION OR DISCHARGE CHARGING GUIDE.

Typical Installations

Suction Discharge Installation 1
Suction Discharge Installation 3
Suction Discharge Installation 2
Suction Discharge Installation 1
Nitrogen Charging Instructions